在電(dian)(dian)機(ji)制造(zao)與運行的關鍵(jian)環節中(zhong),電(dian)(dian)機(ji)絕(jue)緣檢測顯得尤為重要,它直接(jie)關系到電(dian)(dian)機(ji)的性能和運行安全。我國依據GB755、G14711、GB12350等(deng)標準,對電(dian)(dian)機(ji)絕(jue)緣電(dian)(dian)阻(zu)試(shi)驗(yan)設(she)定(ding)了嚴格的規(gui)范(fan)。
絕緣電(dian)(dian)(dian)阻測試(shi)主要依靠兆(zhao)歐表(biao)進行(xing),兆(zhao)歐表(biao)分為手搖式和電(dian)(dian)(dian)子式,其規格需根據電(dian)(dian)(dian)機的額(e)定(ding)電(dian)(dian)(dian)壓來確定(ding),常見的規格包括250V、500V、1000V和2500V等。選(xuan)購兆(zhao)歐表(biao)時,應(ying)嚴格依據電(dian)(dian)(dian)機的額(e)定(ding)電(dian)(dian)(dian)壓進行(xing)選(xuan)擇。
繞組(zu)絕緣電(dian)阻的測(ce)量
在選用(yong)(yong)(yong)兆歐表(biao)(biao)時,需依據電機的(de)(de)(de)額定電壓進行選擇,不同電壓等級(ji)的(de)(de)(de)電機應(ying)選用(yong)(yong)(yong)相應(ying)規(gui)格(ge)的(de)(de)(de)兆歐表(biao)(biao)。對于埋置(zhi)在繞組內的(de)(de)(de)熱敏元件(如PTC、PT100),一般選用(yong)(yong)(yong)250V規(gui)格(ge)的(de)(de)(de)兆歐表(biao)(biao)。
測量方法與要(yao)求
電(dian)(dian)機(ji)絕(jue)緣電(dian)(dian)阻檢(jian)測需在冷(leng)態和熱態下分(fen)別(bie)進行(xing)。熱態檢(jian)測通(tong)常(chang)在電(dian)(dian)機(ji)繞(rao)(rao)組(zu)烘(hong)干過程中進行(xing),而(er)冷(leng)態檢(jian)測則在檢(jian)查試(shi)(shi)(shi)驗時(shi)進行(xing)。對于不同繞(rao)(rao)組(zu),需分(fen)別(bie)測量其對機(ji)殼和相互間的(de)絕(jue)緣電(dian)(dian)阻。在試(shi)(shi)(shi)驗過程中,不參(can)與(yu)試(shi)(shi)(shi)驗的(de)繞(rao)(rao)組(zu)應與(yu)機(ji)殼可靠連接。若電(dian)(dian)機(ji)繞(rao)(rao)組(zu)已(yi)接成(cheng)Y形或△形,則只(zhi)能(neng)檢(jian)測繞(rao)(rao)組(zu)與(yu)機(ji)殼間的(de)絕(jue)緣電(dian)(dian)阻。
兆歐表使(shi)用注意事(shi)項
在使用(yong)兆歐表前(qian),需檢查儀表狀(zhuang)態(tai),如(ru)手(shou)搖式兆歐表,短接引接線時(shi)指(zhi)(zhi)針應歸“0”位,斷開引接線時(shi)指(zhi)(zhi)針應指(zhi)(zhi)向無窮大。使用(yong)后,應將兩接頭短接放電,以避免對人體造成傷(shang)害。
測量結果與(yu)判定
電機熱態絕緣電阻應低于冷態,不同電機根據標準規定了最低限定值。吸收比和極化(hua)指(zhi)數也是衡量絕緣(yuan)電(dian)阻(zu)的重要指標。在(zai)電(dian)機的絕緣(yuan)電(dian)阻(zu)檢測(ce)中,這些指標都需得到充分關注(zhu)。
下一篇: 防爆振動電機詳解
|
|
(版權所有 防爆云平臺 © Copyright 2009 - 2024 . All Rights Reserved.)
違法和(he)不(bu)良信(xin)息舉(ju)報投訴電話:0377-62377728 舉報郵箱:fbypt@bjly.net.cn